Product | MA1 | Detail Data

Acoustical operating principle Pressure transducer
Directional Pattern Omnidirectional
Frequency Range 20 Hz - 20 kHz
Sensitivity at 1 kHz into 1 kohm 30 mV/Pa -30 dBV +/- 3 dB uncalibrated | 30 mV/Pa -30 dBV +/- 0,5 dB Calibrated (via software)
Rated Impedance 50 Ohms
Rated load impedance 1000 Ohms
Equivalent noise level, CCIR¹⁾ 39 dB
Equivalent noise level, A-weighted¹⁾ 27 dB-A
Maximum SPL for THD 0.5%²⁾ 132 dB
Signal-to-noise ratio, CCIR (re. 94 dB SPL)¹⁾ 55 dB
Signal-to-noise ratio, A-weighted (re. 94 dB SPL)¹⁾ 67 dB
Maximum output voltage 10 dBu
Supply voltage (P48, IEC 61938) 48 V ± 4 V
Current consumption (P48, IEC 61938) 3 mA
Matching connector XLR3F
Weight 37 g
Diameter 23 mm
Length 117 mm
Operating conditions 0 °C - +70 °C (32 °F - 158 °F); max. 90 % at +20 °C
Transport/storage conditions −20 °C - +70 °C (−4 °F - 158 °F); max. 90 % at +20 °C

1) according to IEC 60268-1; CCIR-weighting acccording to CCIR 468-3, quasi peak; A-weighting according to IEC 61672-1, RMS

2) measured as equivalent el. input signal

Diagrams

Omni MA 1

Omni MA 1 Omni MA 1