Product | M 49 V | Detail Data
Acoustical operating principle | Pressure gradient transducer |
---|---|
Directional Pattern | variable (omnidirectional...cardioid…figure-8) |
Frequency Range | 40 Hz...16 kHz |
Sensitivity at 1 kHz into 1 kohm | 6.5/8/10 mV/Pa ± 1 dB -43.5/-42/-40 dBV |
Rated Impedance | 200 ohms |
Rated load impedance | 1000 ohms |
Equivalent noise level, CCIR¹⁾ | 32/30/30 dB |
Equivalent noise level, A-weighted¹⁾ | 21/20/19 dB-A |
Maximum SPL for THD 0.5%²⁾ | 125 dB (cardioid) |
Signal-to-noise ratio, CCIR (re. 94 dB SPL)¹⁾ | 62/64/64 dB |
Signal-to-noise ratio, A-weighted (re. 94 dB SPL)¹⁾ | 73/74/75 dB |
Maximum output voltage | 300 mV ~ - 8 dBu |
Power supply | NM V |
Required connectors/Microphone | KC 5 cable (7-pin) |
Required connectors / Power supply unit - output | XLR 3 F |
Weight | 800 g |
Diameter | 80 mm |
Length | 163 mm |
1) according to IEC 60268-1; CCIR-weighting acccording to CCIR 468-3, quasi peak; A-weighting according to IEC 61672-1, RMS
2) measured as equivalent el. input signal