Product | USM69 | Detail Data
Acoustical operating principle | Pressure gradient transducer |
---|---|
Directional Pattern | Omnidirectional, wide-angle cardioid, cardioid, hypercardioid, figure-8 |
Frequency Range | 20 Hz ... 20 kHz |
Sensitivity at 1 kHz into 1 kohm | 13 mV/Pa |
Rated Impedance | 150 ohms |
Rated load impedance | 1 kohms |
Equivalent noise level, CCIR¹⁾ | 24 dB |
Equivalent noise level, A-weighted¹⁾ | 13 dB-A |
Maximum SPL for THD 0.5%²⁾ | 132 dB |
Signal-to-noise ratio, CCIR (re. 94 dB SPL)¹⁾ | 70 dB |
Signal-to-noise ratio, A-weighted (re. 94 dB SPL)¹⁾ | 81 dB |
Maximum output voltage | 3 dBu |
Supply voltage (P48, IEC 61938) | 48 V ± 4 V |
Current consumption (P48, IEC 61938) | 2 x 0.7 mA |
Matching connector | XLR 3 F |
Weight | 510 g |
Diameter | 30 + 48 mm |
Length | 293 mm |
1) according to IEC 60268-1; CCIR-weighting acccording to CCIR 468-3, quasi peak; A-weighting according to IEC 61672-1, RMS
2) measured as equivalent el. input signal